I. Temel Doğruluk Doğrulaması
1. Repeatability Test: Measure 20 times consecutively using a standard part. The repeatability accuracy should be ≤0.8μm (≤0.3μm for high-precision models). If the standard deviation is >1,2μm, kalibrasyon gereklidir.
2. Systematic Error Detection: Measure standard parts of different sizes (e.g., 10mm, 50mm, 100mm). If the deviation is consistently >±2,5μm, telafi gereklidir.
3. Geometrik Doğruluk Doğrulaması:
Guide rail straightness: Error per meter >2μm
Worktable flatness: Full stroke error >3μm
Three-axis perpendicularity: Angular error >5 yay saniyesi.
II. Prob Sistemi Değerlendirmesi
Calibration ball diameter consistency: If the measurement difference in different directions by the same probe is >0.8μm or the roundness error is >0,5μm, yeniden kalibrasyon gereklidir.
Multi-probe consistency: If the deviation of each probe measuring the same dimension is >2μm, prob ilişkisinin kalibrasyona ihtiyacı vardır.
III. Sıcaklık ve Bakım Denetimi
Sıcaklık Kararlılığı: Ortam sıcaklığının ±0,5 derecenin üzerindeki değişimleri doğruluğu etkileyebilir.
Günlük Bakım: Konumlandırma deliklerini aşınma (büyüme veya deformasyon gibi) açısından düzenli olarak temizleyin ve inceleyin; Ağır vakalarda onarım veya değiştirme gereklidir.